Technical Specifications
Unit Size: 1.5m(W)×4.2m(H) Standard Modules
Weight Capacity: ≤800kg/m²
Thermal U-Value: 1.2-1.8 W/m²K
Sound Insulation: Rw 45-50dB
Performance Parameters
Wind Resistance: Up to 6000Pa (Class C5)
Water Penetration: Class 4A (ASTM E331)
Air Permeability: Class 4 (ASTM E283)
Seismic Movement: ±50mm Horizontal
System Composition
Modular Units: Factory-Prefabricated Aluminum Frames
Glazing Options: Double/Triple Glazing, Low-E Coating
Sealant System: Structural Silicone & EPDM Gaskets
Joints: 15-20mm Expansion Gaps
Material Standards
Aluminum Alloy: 6063-T6 (AAMA 303)
Thermal Break: 34mm Polyamide Barrier
Glass Compliance: EN 12150/ISO 12543
Installation Features
Tolerance Absorption: ±15mm
Installation Speed: 20-30 units/day
Maintenance Access: Integrated Fall Protection
Key Applications
Skyscraper Facades
Airport Terminals
Commercial Complexes
Mixed-Use Developments